Low noise air source Heat Pump is different from traditional electric heating and gas heating because the air source heat pump can use low-grade energy to produce high-grade energy, making it more efficient, energy-saving, environmentally friendly and safe. Its main components include indoor unit, outdoor unit, control system, etc.
The core technology of the low-noise air source heat pump is the use of inverter technology, which not only enables precise control of indoor temperature, but also greatly reduces the noise level, improves efficiency, saves energy, and thus reduces operating costs. It operates by absorbing heat from the air through the outdoor unit, transporting it to the indoor unit through pipes, and then releasing the heat into the indoor air to achieve heating or cooling of the indoor air. Its characteristic is that it is not affected by the change of outdoor temperature and can work normally in a low temperature environment of -25°C. It has the advantages of high reliability, energy saving and long life. Meanwhile, since it does not need to burn any substance, it does not produce any waste gas and pollutants, which is a very environmentally friendly way of heating.

|
Unit Model |
DKX(L)RS-11l/CC |
DKX(L)RS-18I/CC |
DKX(L)RS-18Ⅱ/CC |
DKX(L)RS-26Ⅱ/UC |
DKX(L)RS-36Ⅱ/LC |
DKX(L)RS-44Ⅱ/LC |
|
|
Power supply specifications |
220V~50Hz |
220V~50Hz |
380V/3N~50Hz |
380V/3N~50Hz |
380V/3N~50Hz |
380V/3N~50Hz |
|
|
Nominal heat production |
Nominal heat production(KW) |
5.8 |
10.5 |
10.77 |
15 |
18 |
22 |
|
Nominal heating input power(KW) |
2.52 |
4.2 |
4.04 |
5.8 |
8.2 |
8.8 |
|
|
Nominal current(A) |
11.65 |
20.5 |
8.08 |
11.6 |
17.85 |
17.85 |
|
|
Energy efficiency ratio |
2.3 |
2.5 |
2.67 |
2.6 |
2.19 |
2.5 |
|
|
Nominal cooling |
Nominal cooling capacity(KW) |
7.3 |
12 |
12.5 |
16 |
22.5 |
25 |
|
Nominal refrigeration input power(KW) |
2.85 |
4.4 |
4.5 |
5.9 |
8.9 |
9.6 |
|
|
Nominal current(A) |
12.98 |
20 |
9.8 |
11.85 |
19.2 |
19.65 |
|
|
Energy efficiency ratio |
2.52 |
2.73 |
2.78 |
2.71 |
2.5 |
2.6 |
|
|
Heat production |
Rated water discharge temperature℃ |
41 |
41 |
41 |
41 |
41 |
41 |
|
Max. water discharge temperature℃ |
60 |
60 |
60 |
60 |
60 |
60 |
|
|
Refrigeration |
Rated water discharge temperature℃ |
7 |
7 |
7 |
7 |
7 |
7 |
|
Max. Power Input(kW) |
3.7 |
5.8 |
5.85 |
8.5 |
13.5 |
13.5 |
|
|
Max. Current Input(A) |
16.8 |
27 |
11.7 |
17 |
27 |
27 |
|
|
Waterproof grade |
IPX4 |
IPX4 |
IPX4 |
IPX4 |
IPX4 |
IPX4 |
|
|
Compressor |
Copeland 34KS Scroll |
Copeland 52KS Scroll |
Copeland 61KS Scroll |
Invarte 185 Scroll |
Copeland 2*61KS Scroll |
Copeland 2*61KS Scroll |
|
|
Refrigerant (charge quantity) |
R22/2.8 |
R22/4.6 |
R22/4.8 |
R22/5 |
R22/2*4.5 |
R22/2*4.8 |
|
|
Waterway side |
Type |
High efficiency tank |
High efficiency tank |
High efficiency tank |
High efficiency tank |
High efficiency tank |
High efficiency tank |
|
Inlet and outlet water pipe size |
1.2" / DN32 internal teeth |
1.2" / DN32 internal teeth |
1.2" / DN32 internal teeth |
1.2" / DN32 internal teeth |
1.5" / DN40 external teeth |
1.5" / DN40 external teeth |
|
|
Circulating water flow(m³\h) |
2.3 |
3.5 |
3.5 |
5 |
7.5 |
7.5 |
|
|
Main pipe diameter |
DN32 |
DN32 |
DN32 |
DN32 |
DN40 |
DN40 |
|
|
Water-side pressure loss(kPa) |
≤42 |
≤50 |
≤50 |
≤50 |
≤42 |
≤42 |
|
|
Power cord specifications |
4 square copper wire |
6 square copper wire |
4 square copper wire |
6 square copper wire |
6 square copper wire |
6 square copper wire |
|
|
Dimension |
822x344x1300 |
1125x410x1535 |
1125x410x1535 |
860x820x1270 |
1424*785*1210 |
1424*785*1350 |
|
|
Net weight of the unit(kg) |
100 |
170 |
170 |
200 |
305 |
325 |
|
|
Gross weight of the unit(kg) |
120 |
195 |
195 |
230 |
340 |
360 |
|
|
Operating noise(dB(A)) |
<54dB(A) |
<56dB(A) |
<56dB(A) |
<65dB(A) |
<65dB(A) |
<65dB(A) |
|

Product Advantages
1. Environmental protection and energy saving
The low-noise air source heat pump adopts environmentally friendly refrigerant, which will not cause pollution to the environment. In addition, the equipment has high heating efficiency, which can convert one unit of electric energy into three to four units of heat energy, saving more than 60% of energy than traditional electric ovens and electric heaters.
2. High safety
Low noise air source heat pump is a very safe equipment. It has no open flame and no danger of gas leakage. At the same time, it does not need to build gas pipeline, saving installation cost and time.
3. Low noise
Low-noise air source heat pump adopts quiet technology inside, which can reduce the noise during operation, so that you can enjoy a quiet environment even in the working state. This is very beneficial for those who need to study quietly and rest easily.
4. Easy to operate
Low noise air source heat pump adopts digital control panel, which is very easy to use. Users only need to press the corresponding buttons to achieve temperature adjustment and other operations.
5. Wide application
Low-noise air source heat pump is suitable for a variety of places, including residential, office buildings, shopping malls, schools, etc.. It can not only provide heating, but also perform cooling and dehumidification operations. Therefore, it is a very practical and popular equipment.
Hot Tags: low noise air source heat pump, China low noise air source heat pump manufacturers, suppliers, factory, Wifi Control Air Source Heat Pump, Dual Source Heat Pump Cooling and Heating Unit, Household EVI Air Source Heat Pump, Heating Air Source Heat Pump, Split Air Source Heat Pump, Air To Water Source Heat Pump